    Product Details:

    Place of Origin: Foshan, China
    Brand Name: SHX
    Certification: ISO9001:2015, CE, TUV, BV
    Model Number: SCF33

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 Set
    Price: Negotiation
    Packaging Details: Standard export packing
    Delivery Time: 20 working days
    Payment Terms: L/C, T/T
    Supply Ability: 100 Sets per month
    Contact Now
    Detailed Product Description
    Product Name: 30KVA Diesel Generator Color: Green
    Frequency: 50Hz Running Speed: 1500RPM
    Voltage: 415V / 240V Engine Brand: Cummins
    Alternator Brand: Faraday Control Panel: Smartgen HGM6110N

     

    24KW / 30KVA Cummins Engine Powered Diesel Generator AC 3 Phase Generator

     

    General Feature

    1. Every generator set is subjected to a comprehensive test program which includes 25% load, 50% load, 75% load, 100% load, 110% load and the checking, proving of all control and safety shut-down function.
    2. Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connecting with cables.
    3. Equipped with industrial silencer and flexible exhaust hose.
    4. Equipped with 8-hours operation base tank.
    5. Equipped with CHNT MCCB circuit breaker.
    6. Designed to comply with ISO 8528/GB2820.
    7. Powered by Cummins engine and coupled with Stamford alternator.

    Genset Specifications

     

    Genset model SCF33
    Genset rated power 24KW / 30KVA
    Rated voltage 240V / 415V (adjustable)
    Rated current 42 Amps
    Frequency 50 Hz
    Power factor 0.8 Lagging
    Connecting type 3 phase 4 wire
    Cooling system Closed cycle water-cooled with fan, water tank
    Overall dimension (L×W×H) mm 1800×800×1200
    Weight (kg) 860

     

    Engine Specifications

     

    Diesel Engine
    Brand DCEC CUMMINS
    Model 4BT3.9-G2
    Engine structure 4 cylinders vertical in line, 4 stroke, turbocharged
    Rotating speed 1500 RPM
    Engine cooling method Water-cooled
    Speed governing system Electronic speed governor
    Starting method By 24V batteries
    Engine filter system Dry type air filter ,fuel filter, oil filter, water filter
    Displacement(L) 3.9
    Bore×Stroke(mm) 102×120
    Compression ratio 16.5: 1
    100% Load fuel consumption (litre/h) ≤6.0
    Lube capacity(L) 11

     

    Alternator Specifications

     

    Alternator
    Brand FARADAY
    Model FD1G1-4
    Excite type Brushless self-excited AVR regulation
    Connecting type 3 phase 4 pole
    Steady frequency change 0.50%
    No load voltage ≥95%-105%
    Steady voltage ≤±1%
    Insulation class Class H
    Protection grade IP23

     

    Control System

    • Control, monitor and protect the Generator Set including:
    • High water temperature
    • Low oil pressure
    • Over and under speed
    • Over current
    • Under/Over generator voltage
    • Start and stop failure
    • Low and high battery voltage
    • Charge fail
    • Emergency stop

    INSPECTION AND TEST

     

    1 GENERAL

    1.1 Each engine shall be tested at manufacturer’s workshop to certify the engine output and fuel consumption in accordance with the site operating condition specified by purchaser on the specification datasheet.

    1.2 All relevant information drawings pertinent to the testing and test procedure shall be transmitted to the purchaser in advance of the test date notification.

    1.3 The purchaser shall call for additional testing if test results are unsatisfactory or marginal. Any equipment rejected shall be repaired or replaced to the purchaser’s satisfaction and tests shall be repeated.

    1.4 Any unsatisfactory material, equipment, installation, or workmanship shall be replaced or repaired to the purchasers satisfaction at the manufacturers cost.

    1.5 The engine and generator shall be tested individually in accordance with relevant standards specified above.

    1.6 The completed and individually tested engine and generator shall be assembled onto the base plate with all auxiliaries, instruments and controls for a complete test of the generator set.

     

    24KW / 30KVA Cummins Engine Powered Diesel Generator AC 3 Phase 4 Pole 415V