| Brand Name: | SHX |
| Model Number: | SHX500-ATS |
| MOQ: | 1 Set |
| Price: | USD 28500-32000 / Set |
| Packaging Details: | Plywood case with shock absorbing foam and steel frame bracing |
| Payment Terms: | T/T,L/C,Western Union |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Built for heavy standby duty, this 500 kVA / 400 kW set uses a Perkins 2506A-E15TAG2 six cylinder engine and a Leroy Somer compatible brushless alternator inside a heavy gauge soundproof canopy. The DSE8610 MKII controller manages automatic mains failure start, load transfer and parallel ready operation, so large facilities can restore power without manual intervention.
| Standby Power | 500 kVA / 400 kW |
| Prime Power | 450 kVA / 360 kW |
| Voltage / Frequency | 400/230 V, 50 Hz, three phase, 4 wire |
| Engine Model | Perkins 2506A-E15TAG2, 6 cylinder turbocharged aftercooled |
| Alternator | Brushless, self excited, 100 percent copper, IP23, Class H |
| Controller | Deepsea DSE8610 MKII, parallel ready |
| ATS | Auto mains failure start, load transfer under 10 s |
| Noise Level | 65 dB at 7 m |
| Fuel Tank | 1000 L base tank, about 7 h at 75 percent load |
| Fuel Consumption | 205 g/kWh at 100 percent load |
| Dimensions | 4600 x 1600 x 2200 mm |
| Net Weight | 5200 kg |
Each set is tested at 50, 75, 100 and 110 percent load with full protection function verification before shipment. Packing is plywood case with foam protection; starting batteries, exhaust silencer, connection cables, operation manual and factory test report are included.
| Brand Name: | SHX |
| Model Number: | SHX500-ATS |
| MOQ: | 1 Set |
| Price: | USD 28500-32000 / Set |
| Packaging Details: | Plywood case with shock absorbing foam and steel frame bracing |
| Payment Terms: | T/T,L/C,Western Union |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Built for heavy standby duty, this 500 kVA / 400 kW set uses a Perkins 2506A-E15TAG2 six cylinder engine and a Leroy Somer compatible brushless alternator inside a heavy gauge soundproof canopy. The DSE8610 MKII controller manages automatic mains failure start, load transfer and parallel ready operation, so large facilities can restore power without manual intervention.
| Standby Power | 500 kVA / 400 kW |
| Prime Power | 450 kVA / 360 kW |
| Voltage / Frequency | 400/230 V, 50 Hz, three phase, 4 wire |
| Engine Model | Perkins 2506A-E15TAG2, 6 cylinder turbocharged aftercooled |
| Alternator | Brushless, self excited, 100 percent copper, IP23, Class H |
| Controller | Deepsea DSE8610 MKII, parallel ready |
| ATS | Auto mains failure start, load transfer under 10 s |
| Noise Level | 65 dB at 7 m |
| Fuel Tank | 1000 L base tank, about 7 h at 75 percent load |
| Fuel Consumption | 205 g/kWh at 100 percent load |
| Dimensions | 4600 x 1600 x 2200 mm |
| Net Weight | 5200 kg |
Each set is tested at 50, 75, 100 and 110 percent load with full protection function verification before shipment. Packing is plywood case with foam protection; starting batteries, exhaust silencer, connection cables, operation manual and factory test report are included.